RE: Rule Deactivation

I wouldn't want to press the circular references. Too many loose nuts behind the wheel (ME Included). I was hoping to find a neat workaround - by reading between the lines on some other posts. I can...

View Article


RE: Key-in and Accept-(Left Buttom)Mouse problem

Hi Mishu, 1. I was able to reproduce what you are seeing in the latest version 08.11.09.878. I filed this as defect 651638: Evaluation > Hydrology and Hydraulics > Pass through Contours >...

View Article


RE: Geopak-DTM-Analysis-Profile

Did you follow the steps in this video.communities.bentley.com/.../4729 You select the surfaces first, add them to the dialog list, then click on the create profile icon to switch to that part of the...

View Article

Geopak-DTM-Analysis-Profile

I attached my existing and proposed TIN in the DTM-Analysis-Profile box, then adjusted the scale I would like the profile.  When I tried to create the profile it says No Elements Found.  I'm not sure...

View Article

RE: Cursor turns black when selecting a command on Microstation

You may want to try deleting the following folder and then going back into the software and try again. C:\Users\your user name\AppData\Local\Bentley\MicroStation\8.11\AWtPzEtc3bz25jH6VJkpyA\

View Article


Cursor turns black when selecting a command on Microstation

My mouse appears white on the screen but when I select any command such as to draw a line, move, copy or anything at all the cursor suddenly turns black and I can no longer see the cursor since my...

View Article

RE: Key-in and Accept-(Left Buttom)Mouse problem

I cannot use the 2nd solution because my clients want millimeters and Contours minimum setting for interval is 0.01

View Article

RE: Key-in and Accept-(Left Buttom)Mouse problem

You can change the accuracy within MicroStation>Settings>Design File>Working Units - Accuracy. You will be able to use millimeters after you do that.

View Article


RE: Key-in and Accept-(Left Buttom)Mouse problem

No I can not. My settings is already in millimeters and the interval of Contours is 0.01. Try for example elevation 54.321 and tell me if it worked.

View Article


RE: Superelevation

What is the software you are working with?

View Article

Superelevation

I am having problems with superelvation, I am running an urban section that doesn't need superelevation but I have an intersection that I need to change the cross slope and I cant get it to work. I...

View Article

Image may be NSFW.
Clik here to view.

RE: Geopak Drainage Subareas Automatic Delineation not working

Hi Vinod,yes, it came through and I replied. I resolved the issue - it was inconsistent level symbology applied to the land use shapes. I was expecting a reply from you a couple of day ago... :-)Here...

View Article

Geopak Drainage Subareas Automatic Delineation not working

MicroStation V8i SS3 08.11.09.459Geopak V8i SS2 08.11.07.615I have a drainage design gdn file (2D file) open, a Geopak drainage file (.gdf) open, and all the drainage preferences have been setup. I...

View Article


RE: Rule Deactivation

As mentioned previously We've been stuck with using the MS CAD tools to build geometric elements that require snaps we don't want to rule and then apply civil rules to them. We've also gotten in the...

View Article

Rule Deactivation

I have seen many discussions here about rules, but I have yet to see a good answer to this simple question:Is there ANY way to deactivate rule generation, especially snap rules? These things are...

View Article


Image may be NSFW.
Clik here to view.

RE: Power Civil for SA - SS4 - Station annotation in incorrect place

I have similar problem, but in my case stationing is correct annotate but symbols are located outside horizontal aligment. When I annotate center line or other aligment using Inroads and using the same...

View Article

Power Civil for SA - SS4 - Station annotation in incorrect place

I am having an Issue with my horizontal alignment - stationing annotation.I am working in a projected LO and using the feature definition Geom_CL for my alignments.When turning the Auto annotation...

View Article


RE: Superelevation

I am using Power GEOPAK (SELECT series 4) Version 08.11.09.845 

View Article

RE: Superelevation

By not getting to work, do you mean that when you click to apply the superelevation to the corridor, a list of lanes comes up but since the superelevation points in the template aren't registering, the...

View Article

RE: Cursor turns black when selecting a command on Microstation

Instead of deleting this folder, you might want to rename it. If renaming it fixes the problem, you could name it back to the original, and file by file or folder by folder, you might get to the bottom...

View Article