Hello,
I can't cope with input interface function creating earthworks. I'm able to write a right fill/cut conditions but there must have a different names of strings and get awfull transitions areas without ditches (gaps). I need to make a manual corrects in such places. Is there any solution to manage such thing. Below is part of my input (sections "S" - survey, "D" - ditches levels) and dwg with drawing:
INTERFAC,S7 DITCHES PP,S7 EARTHWORKS
259,INTI
260,1=MC10,2=IA10,3=IA10,4=-11,5=38100,8=38400
261,1=D ,2=ES10,3=IP10,4=5,5= 5.1 ,7=-0.33333
261,1=IGN ,2=IP10,3=RP10,4=5,5= 0.375 ,7=-0.62222
261,1=IGN ,2=RP10,3=RD1P,4=5,5= 0.375 ,7=-0.17778
261,1=IGN ,2=RD1P,3=RP11,4=5,5= 0.375 ,7=+0.17778
261,1=IGN ,2=RP11,3=IP11,4=5,5= 0.375 ,7=+0.62222
261,1=IGN ,2=IP11,3=IW10,4=5,5= 2.1 ,7=+0.33333
261,1=S ,2=IW10,3=IW11,4=5,5= 2.0 ,7=+0.5
261,1=S ,2=IW11,3= ,4=5,5= ,7=+0.66667
262,1=D ,2=ES10,3=RT10,4=5,5= ,7=-0.66667
262,1=IGN ,2=RT10,3=RD1T,4=5,5= 0.20 ,7=-0.0
262,1=IGN ,2=RD1T,3=RT11,4=5,5= 0.20 ,7=-0.0
262,1=IGN ,2=RT11,3=IN10,4=5,5= 0.75 ,7=+0.66667
262,1=S ,2=IN10,3= ,4=5,5= ,7=+0.66667
262,1=S ,2=IN10,3=IN11,4=5,5= 1.00 ,7=+0.0
262,1=S ,2=IN11,3= ,4=5,5= ,7=-0.66667
263,NODI
Best regards
Aleksander Zamorski
[View:/cfs-file/__key/communityserver-discussions-components-files/5922/EARTHWORKS.dwg:50:0]