Error reading idf file in Storm and Sanitary

$
0
0

Let me preface this by stating that I know that S&S is being replaced by SUDA, but at this time the profile generation capabilities for plan creation in SUDA are essentially non-existent so I must continue using S&S.

Using Powerinroads 8.11.9.878, I intermittently get an error when running a storm and sanitary model that starts it cannot read the IDF file.  I do not get this error all the time and I do not get it in earlier SS 2 releases.  Here is some of the output of my S&S design log"

Designing pipe P 3

Results:
Total Flow: 1.2359 cfs Flow From: Upstream

Time of Concentration ENABLED
Tc: 5.3137 min Intensity: 3.2000 in/h
Sum C x Area: 0.3862 ac Ave Runoff Coef: 0.0000

Status: Fixed Slope: 0.0134 ft/ft
Pipe Width: 18.0000 in Pipe Height: 18.0000 in
Depth of Flow: 0.3227 ft Flow Status: Partial
Critical Depth: 0.4150 ft Capacity: 12.1754 cfs
Velocity: 4.4243 ft/s
Froude Number: 1.6389 Flow Regime: SuperCritical


Designing inlet CB 3-1
Error reading from file C:\Users\clint.merrell\Desktop\i_rainfall.idf
Error reading from file C:\Users\clint.merrell\Desktop\i_rainfall.idf

 

The error occurs at different points in the model run, seemingly at random. Sometimes I can get it to run the entire model with no problems. but more often I get the error and the model stops processing. 

I have tried moving the .idf file to a location where I know I have read and write access as an admin, both on network drives and on my primary hard drive.

I'm running windows 10 64-bit.

Anyone have any ideas on how to fix this issue?